Pumps Comparison Apparatus Manufacturer,Supplier and Exporter in India
Product Code : SCL-CELE-14197
Overview
The Pump Comparison Apparatus is
designed for the investigation and comparison of the operating behavior
of different types of pumps — namely centrifugal, piston, and side-channel
pumps.
It provides students with hands-on experience in understanding the functional
differences, performance characteristics, and efficiency of various pump
designs commonly used in engineering applications.
The unit consists of:
- Two centrifugal pumps,
- One piston pump (positive-displacement type), and
- One self-priming side-channel pump.
Each pump is individually driven by a
three-phase AC motor, with the centrifugal pumps featuring variable
speed control via a frequency converter. The side-channel pump offers a
unique hybrid operation, functioning both as a centrifugal and positive
displacement pump, and can even pump gases, making it suitable for
demonstrating multi-phase flow principles.
A closed water circuit allows safe and
continuous operation.
Torque, pressure, and flow measurements are collected via sensors, displayed
digitally, and can be recorded on a PC using the included USB data
acquisition software. This enables real-time analysis, plotting of pump
and system characteristic curves, and determination of operating points
and efficiencies.
A free motor position with a
reversible, variable-speed AC motor is provided for testing additional pump
types.
Key
Features
- Comparison of centrifugal, piston, and side-channel pump
performance.
- Centrifugal pumps operable individually, in parallel, or in
series.
- Independent three-phase AC motors for
each pump.
- Variable-speed control for
centrifugal and auxiliary motors.
- Closed-loop water circuit for
safe, continuous operation.
- Measurement of flow rate, pressure, torque, and power.
- Digital display and PC
data acquisition via USB.
- Included software for
plotting pump and system characteristic curves.
- Free position with
reversible motor for additional pump experiments.
- Comprehensive instructional material included for guided
learning.
Technical
Specifications
|
Component |
Specification |
|
Centrifugal Pumps (2x) |
|
|
– Maximum Flow Rate (Q) |
300 L/min |
|
– Maximum Head (H) |
16.9 m |
|
– Nominal Speed |
2900 min?¹ |
|
– Motor Power Output |
750 W (each) |
|
– Speed Range |
750 – 3000 min?¹ |
|
Side-Channel Pump (Self-Priming, One-Stage) |
|
|
– Flow Rate (Q) |
83.3 L/min |
|
– Head (H) |
50 m |
|
– Nominal Speed |
1450 min?¹ |
|
– Motor Power Output |
1.1 kW |
|
– Speed |
1500 min?¹ |
|
Piston Pump (Positive Displacement) |
|
|
– Flow Rate (Q) |
17 L/min |
|
– Head (H) |
60 m |
|
– Nominal Speed |
405 min?¹ |
|
– Motor Power Output |
0.55 kW |
|
– Speed |
1500 min?¹ |
|
Additional Motor (Reversible) |
|
|
– Power Output |
0.75 kW |
|
– Speed Range |
750 – 3000 min?¹ |
|
Measuring Ranges |
|
|
– Flow Rate |
0 – 500 L/min |
|
– Intake Pressure |
–1 – 1.5 bar |
|
– Delivery Pressure |
0 – 10 bar |
|
– Torque |
0 – 15 Nm |
|
– Speed |
0 – 3000 min?¹ |
|
– Electrical Power Consumption |
0 – 2000 W |
|
Data Acquisition |
Via USB with Windows-compatible software |
|
Power Supply |
400 V, 50/60 Hz, 3 Phase (or 230 V, 60 Hz, 3 Phase) |
Experiments
& Learning Objectives
- Investigation and comparison of operating behavior of:
- Centrifugal pumps
- Piston pump (positive displacement)
- Side-channel pump
- Plotting of pump characteristic curves (H-Q curves).
- Plotting of system characteristic curves.
- Determination of pump efficiency under
varying conditions.
- Investigation of parallel and series configurations of
centrifugal pumps.
- Comparison of different pump types based on performance data.
Educational
Objectives
- Understand the principles of operation of centrifugal and
positive-displacement pumps.
- Study the relationship between flow rate, head, and power.
- Explore series and parallel pump configurations.
- Determine and interpret pump efficiency curves.
- Learn data acquisition and analysis techniques for pump
systems.
Required
Services
- Electrical Supply: 400
V, 50/60 Hz, 3 Phase
(alternative: 230 V, 60 Hz, 3 Phase)