Reynold's Apparatus Manufacturer,Supplier and Exporter in India
Product Code : SCL-CELE-14090
The described apparatus is a classic educational unit
designed to experimentally verify Reynolds's demonstration of fluid flow
regimes, a cornerstone of fluid mechanics. The setup facilitates the
visualization and quantification of the transition between laminar flow
and turbulent flow. Water is drawn from a Constant Head Tank
through a glass tube, controlled by a cock at the exit. The flow rate is
precisely measured using a measuring cylinder and a stopwatch.
Critically, a centralized capillary tube introduces a dye streak at the bell
mouth entrance, allowing for visual observation of the dye's behavior to
identify the flow type. This empirical observation enables the direct
calculation of the dimensionless Reynolds Number (Re), which dictates
the flow regime.
Objectives: Flow Regime Study
|
Objective |
Key Concept Investigated |
Relevance and Application |
|
To study different types of flow |
Laminar, Transition, and Turbulent Regimes |
Visualizing and defining the three primary states of fluid
motion in a pipe. |
|
To determine the Reynolds Number and hence the type of flow |
Critical Reynolds Number (Rec) |
Quantifying the dimensionless number (Re) used to predict
whether flow is laminar (Re < 2000) or turbulent (Re > 4000). |
Technical Specifications: Reynolds Apparatus Components
|
Component |
Parameter / Material |
Value / Feature |
|
Flow Tube |
Material |
Borosilicate Glass |
|
Dye Vessel |
Material |
SS (Stainless Steel), Suitable Capacity |
|
Dye Delivery |
Capillary Tube Material |
Copper / Stainless Steel |
|
Water Supply |
Constant Head Water Tank Capacity |
40 Liters |
|
Recirculation |
Water Circulation Pump |
FHP Pump |
|
System Storage |
Sump Tank Capacity |
60 Liters |
|
Flow Measurement |
Method |
Using Measuring Cylinder and Electronic Stop Watch |
|
Structure |
Housing |
Good quality painted structure |
|
Controls |
Control Panel |
Standard make, On/Off Switch, Mains Indicator, etc. |