Pacemaker with Simulator Manufacturer,Supplier and Exporter in India
Product Code : SCL-MDE-12435
Indian Lab Suppliers offers the Pacemaker with Simulator (Product ID: 12435) as part of its Medical Diagnostic Equipment range under Hospital Lab Equipment. This trainer combines the same Internal-External Pacemaker demo circuit as our standalone Internal-External Pacemaker Demo Type Trainer with a built-in Pacemaker Simulator that acts as a "subject" load for the pacemaker, so the full working cycle can be studied on one bench unit. This is an educational demo instrument, not a device intended for implantation or clinical use.
Quick Answer
This is a demo-type Internal-External Pacemaker trainer bundled with a built-in Pacemaker Simulator that acts as the subject/load for the pacemaker section. The pacemaker side offers Fixed and Demand modes, a rate-control knob (pulse rate 30 to 150 BPM, approx.), positive pulse duration approx. 2mS, adjustable output intensity (0 to 9V) and an ECG sync-pulse input (approx. 9V). The built-in simulator supplies an adjustable heart-rate output (30 to 120 BPM, approx.), a PQRST ECG output of approx. 5mV via a 4mm socket, a heart-pulse sync input to the pacemaker, and selectable arrhythmias (AV Block, Bradycardia and Tachycardia) with adjustable rate, rhythm and threshold.
Key Features
Internal-External Pacemaker demo trainer with built-in Pacemaker Simulator · Fixed and Demand modes, rate-control knob, pulse rate 30 to 150 BPM (approx.) · Positive pulse duration approx. 2mS · Output intensity adjustable 0 to 9V · ECG sync-pulse input, approx. 9V · Disc electrodes; audible & visible indication · Built-in Simulator: adjustable heart rate 30 to 120 BPM (approx.) · PQRST ECG output approx. 5mV via 4mm socket · Heart-pulse sync output to the pacemaker · Selectable arrhythmias: AV Block, Bradycardia, Tachycardia · Adjustable rate, rhythm & threshold for the pacemaker output as a load/subject · Heart-pulse simulation shown on top of the instrument · Optional PC connectivity
Key Specifications
| Parameter | Specification |
|---|---|
| Type | Internal-External Pacemaker demo trainer with built-in Pacemaker Simulator |
| Pacemaker modes | Fixed and Demand |
| Pulse rate | 30 to 150 BPM (±), rate-control knob |
| Pulse duration | Positive, approx. 2mS (±) |
| Output intensity | 0 to 9V, adjustable |
| ECG sync input | Approx. 9V (±) |
| Electrodes | Disc electrodes; audible & visible indication |
| Test points | Top of instrument, via 2mm socket |
| Simulator heart rate | 30 to 120 BPM (±), adjustable |
| Simulator ECG output | PQRST, approx. 5mV (±), via 4mm socket |
| Simulator arrhythmias | AV Block, Bradycardia, Tachycardia; adjustable rate, rhythm & threshold |
| Power supply | 230V / 50Hz |
| Dimensions | Approx. 250 x 75 x 250mm (±) – source sheet shows "250X7X250mm," read here as a likely digit-drop typo for 75mm to match the depth figure on our standalone pacemaker trainer; please verify with us before specifying |
| Optional | PC connectivity |
| Suggested study/experiments | Pacemaker working; need for Internal vs. External modes; electrode placement; Demand vs. Fixed mode using the built-in simulator; simulator working; signal processing and the working of each block |
| Standard accessories | Operating manual covering instrument working, operating & installation procedure, block diagrams, connection diagrams, electrode placement, standard signals & actual output signal, calculations, tables, troubleshooting, and an experiments list |
Where This Is Used
This trainer suits biomedical engineering and paramedical training laboratories that want the pacemaker demo circuit and its test subject/load combined on a single bench unit. It is the simulator-equipped counterpart to our Internal-External Pacemaker Demo Type Trainer (listed under the slug "implantable-pacemaker"), and sits alongside our D.C. Defibrillator Trainer and D.C. Defibrillator Simulator within the wider Medical Diagnostic Equipment range. Browse the full laboratory equipment range for related training and diagnostic instruments.
Why Buy from Indian Lab Suppliers
Indian Lab Suppliers is an India-based laboratory equipment manufacturer and exporter supplying hospital and biomedical training equipment to institutions and distributors worldwide. Every order can be supplied with export documentation, and a Certificate of Origin is available on request to support customs clearance.
Frequently Asked Questions
How does this differ from the standalone pacemaker trainer?
This version adds a built-in Pacemaker Simulator that acts as the subject/load for the pacemaker section, so both sides of the working cycle can be studied on one bench unit instead of pairing two separate instruments.
Is this suitable for actual implantation or patient use?
No. This is a demo-type educational trainer for biomedical instrumentation study, not a clinical or implantable device.
What arrhythmias can the built-in simulator generate?
AV Block, Bradycardia and Tachycardia, with adjustable rate, rhythm and threshold.
What ECG output does the simulator provide?
A PQRST waveform of approximately 5mV, available via a 4mm socket, alongside a heart-pulse sync signal fed to the pacemaker.
What does the study material cover?
Pacemaker working, the need for Internal vs. External modes, electrode placement, Demand vs. Fixed mode operation using the built-in simulator, and signal processing at each functional block.
Related Categories
Explore the full Medical Diagnostic Equipment category, part of our wider laboratory equipment catalogue.
Request a Quote
For pricing, lead time and export documentation, please contact us or submit your requirement through our lab tender page.