Pacemaker Simulator Manufacturer,Supplier and Exporter in India
Product Code : SCL-MDE-12436
Indian Lab Suppliers offers the Pacemaker Simulator (Product ID: 12436) as part of its Medical Diagnostic Equipment range under Hospital Lab Equipment. This is a standalone "dummy patient" signal source built for testing and calibrating a pacemaker, generating simulated arrhythmia patterns so students and technicians can practise pacemaker interfacing without a live subject.
Quick Answer
This is a standalone Pacemaker Simulator that acts as a "dummy patient" for testing and calibrating a pacemaker. Simulated arrhythmias (AV Block, Bradycardia and Tachycardia) are selected via a press switch, with a PQRST output, pulse rate adjustable 40 to 120 BPM (approx.), output voltage adjustable 0 to 9V, ECG output approx. 10mV and pulse output 0 to 9V. It indicates Pace Pulse, Sync and Arrhythmia status, with an adjustable threshold for the pacemaker input and power-to-patient indication.
Key Features
Standalone Pacemaker Simulator, dummy-patient signal source · Simulated arrhythmias selected via press switch: AV Block, Bradycardia, Tachycardia · PQRST output, pulse rate adjustable 40 to 120 BPM (approx.) · Output voltage adjustable 0 to 9V · ECG output approx. 10mV · Pulse output 0 to 9V · Indication for Pace Pulse, Sync and Arrhythmia · Adjustable threshold for pacemaker input, with power-to-patient indication
Key Specifications
| Parameter | Specification |
|---|---|
| Function | Dummy-patient signal source for pacemaker testing and calibration |
| Arrhythmia selection | Press switch: AV Block, Bradycardia, Tachycardia |
| PQRST / pulse rate | Adjustable 40 to 120 BPM (±) |
| Output voltage | Adjustable 0 to 9V |
| ECG output | Approx. 10mV (±) |
| Pulse output | 0 to 9V (±) |
| Indication | Pace Pulse, Sync, Arrhythmia; adjustable threshold for pacemaker input; power-to-patient indication |
| Power supply | 230V / 50Hz – source sheet shows "23V, 50Hz," read here as a likely digit-drop typo consistent with the 230V/50Hz supply used across this trainer family; please verify with us before specifying |
| Dimensions | Approx. 250 x 75 x 250mm (±) |
| Suggested study/experiments | Signal patterns for AV Block, Bradycardia and Tachycardia; studying a dummy heart; testing and calibrating a pacemaker using the simulator; Demand vs. Sync mode |
| Standard accessories | Operating manual covering instrument working, operating & installation procedure, block diagrams, connection diagrams, electrode placement, standard signals & actual output signal, calculations, tables, troubleshooting, and an experiments list |
Where This Is Used
This simulator is intended for biomedical engineering and paramedical training laboratories that need a "dummy patient" signal source for pacemaker testing and calibration practice. It is designed to pair with our Internal-External Pacemaker Demo Type Trainer and complements our Pacemaker with Simulator (which has an equivalent simulator built in), alongside our D.C. Defibrillator Simulator within the wider Medical Diagnostic Equipment range. Browse the full laboratory equipment range for related training and diagnostic instruments.
Why Buy from Indian Lab Suppliers
Indian Lab Suppliers is an India-based laboratory equipment manufacturer and exporter supplying hospital and biomedical training equipment to institutions and distributors worldwide. Every order can be supplied with export documentation, and a Certificate of Origin is available on request to support customs clearance.
Frequently Asked Questions
What does this simulator do?
It acts as a "dummy patient," generating simulated arrhythmia signals so a pacemaker can be tested and calibrated without a live subject.
How does it differ from the Pacemaker with Simulator?
This is a standalone dummy-patient unit for use with our separate Internal-External Pacemaker Demo Type Trainer, whereas the Pacemaker with Simulator has an equivalent simulator function built into the pacemaker trainer itself.
What arrhythmias can it simulate?
AV Block, Bradycardia and Tachycardia, selected via a press switch.
What is the pulse-rate range?
Approximately 40 to 120 BPM, adjustable.
What does the study material cover?
Signal patterns for AV Block, Bradycardia and Tachycardia, studying a dummy heart, testing and calibrating a pacemaker using the simulator, and Demand vs. Sync mode operation.
Related Categories
Explore the full Medical Diagnostic Equipment category, part of our wider laboratory equipment catalogue.
Request a Quote
For pricing, lead time and export documentation, please contact us or submit your requirement through our lab tender page.