Blood Pressure Measurement Trainer Manufacturer,Supplier and Exporter in India

Blood Pressure Measurement Trainer

Product Code : SCL-MDE-12444

Indian Lab Suppliers offers the Blood Pressure Measurement Trainer (Product ID: 12444) as part of its Medical Diagnostic Equipment range under Hospital Lab Equipment. This is an educational trainer that measures systolic and diastolic blood pressure using the Korotkoff-sound method – letting students both see the digital reading and listen to the Korotkoff sounds via headphone – and is specially designed for classroom and laboratory teaching rather than routine clinical use.

Quick Answer

This trainer measures blood pressure using the Korotkoff (auscultatory) method: a cuff is tied around the upper arm and a microphone is applied over the brachial artery, with the resulting signal passed through a pre-amplifier and a band-pass filter (25 to 125Hz bandwidth) to achieve a good signal-to-noise ratio. The system locks the systolic reading on the first Korotkoff sound and the diastolic reading on the last, automatically deflating the cuff 2 to 5 seconds after the diastolic value is determined, with a measurement range of 30 to 280mmHg and an accuracy of ±4mmHg.

Key Features

Measures both systolic and diastolic blood pressure accurately · Korotkoff sound detection via cuff and brachial-artery microphone · Pre-amplifier and band-pass filter (25 to 125Hz) for good signal-to-noise ratio · Automatic systolic/diastolic lock-in on first/last Korotkoff sound · Automatic cuff deflation, 2 to 5 seconds after diastolic determination · Separate test points to observe the waveform after each block · Self-contained and easy to operate · LCD digital display · Korotkoff sound audible via headphone · Oscilloscope-compatible for waveform observation · Specially designed for educational use

Key Specifications

ParameterSpecification
Method Korotkoff sound (auscultatory), via cuff and brachial-artery microphone; source spec sheet separately lists an oscillometric-method reference under Technical Specifications – both descriptions are presented here exactly as supplied, please verify with us which method applies to your unit
Signal path Pre-amplifier, then band-pass filter, 25 to 125Hz
Systolic/diastolic detection Locked on first Korotkoff sound (systolic) and last Korotkoff sound (diastolic)
Cuff deflation Automatic, rapid air release, 2 to 5 seconds after diastolic determination
Display Large-screen digital display
Inflation Automatic, built-in pump
Sensor Pressure-detection mechanical capacitance pressure sensor
Measurement range 30 to 280mmHg
Accuracy Blood pressure ±4mmHg
Monitoring options Korotkoff sound audible via headphone; waveform observable via oscilloscope; separate test points after each functional block

Where This Is Used

This trainer suits biomedical engineering and nursing/paramedical training laboratories teaching blood-pressure measurement principles – Korotkoff-sound detection, signal filtering, and systolic/diastolic determination – as a hands-on complement to classroom theory. It sits alongside our other blood-pressure and vital-signs trainers within the wider Medical Diagnostic Equipment range. Browse the full laboratory equipment range for related training and diagnostic instruments.

Why Buy from Indian Lab Suppliers

Indian Lab Suppliers is an India-based laboratory equipment manufacturer and exporter supplying hospital and biomedical training equipment to institutions and distributors worldwide. Every order can be supplied with export documentation, and a Certificate of Origin is available on request to support customs clearance.

Frequently Asked Questions

How does this trainer measure blood pressure?
Using the Korotkoff (auscultatory) method: a cuff on the upper arm and a microphone over the brachial artery pick up the Korotkoff sounds, which are filtered and used to lock in the systolic (first sound) and diastolic (last sound) readings.

Can I listen to the Korotkoff sounds directly?
Yes, the Korotkoff sound can be monitored via a headphone in addition to the digital display reading.

What is the measurement range and accuracy?
30 to 280mmHg, with an accuracy of ±4mmHg.

Can the waveform be observed on external equipment?
Yes, an oscilloscope can be connected to observe the waveform, and separate test points are provided after each functional block.

Is this suitable for classroom teaching?
Yes, it is specially designed for educational use, self-contained and easy to operate.

Related Categories

Explore the full Medical Diagnostic Equipment category, part of our wider laboratory equipment catalogue.

Request a Quote

For pricing, lead time and export documentation, please contact us or submit your requirement through our lab tender page.

   