Patient Monitor ECG_Sp02_BP_Remp._Respiration Monitor Manufacturer,Supplier and Exporter in India
Product Code : SCL-MDE-12411
Indian Lab Suppliers offers the Patient Monitor ECG_Sp02_BP_Remp._Respiration Monitor (Product ID: 12411), a 12-inch six-parameter patient monitor in our Medical Diagnostic Equipment range under Hospital Lab Equipment.
Quick Answer
This is a 12-inch multi-parameter patient monitor covering six standard parameters — ECG, Respiration, NIBP, SpO2, Temperature, and PR / HR — for continuous bedside patient monitoring where respiration and body temperature tracking are required in addition to cardiac and blood-pressure monitoring. It is the 6-parameter counterpart to our 5-parameter ECG/NIBP/SpO2/PR/HR patient monitor (which does not include respiration or temperature channels).
Key Features
12-inch monitor display · Six parameters: ECG, Respiration, NIBP, SpO2, Temperature, PR / HR · Selectable 5-lead or 3-lead ECG acquisition · Adjustable ECG gain (±2.5, ±5.0, ±10, ±20 mm/mV, auto) · Built-in ST-segment monitoring · Arrhythmia (ARR) detection covering Asystole, VFib/VTac, Couplet, Bigeminy, Trigeminy, R-on-T, VT>2, PVC, Tachycardia and Bradycardia · Impedance-based respiration measurement (R-F / RA-LL) · Oscillometric NIBP with Manual, Auto and STAT modes across Adult / Pediatric / Neonatal ranges · 2-channel temperature measurement
Key Specifications
| Parameter | Detail |
|---|---|
| Display | 12 inch |
| Parameters Monitored | ECG, Respiration, NIBP, SpO2, Temperature, PR / HR |
| ECG Lead Modes | 5-lead (2ch waveform) or 3-lead (1ch waveform); gain ±2.5/±5.0/±10/±20 mm/mV, Auto |
| HR Range | Adult: 15–300 bpm; Neo/Ped: 15–350 bpm; Accuracy ±1% or ±1bpm (whichever greater) |
| ECG Bandwidth | Surgery: 1–15 Hz; Monitor: 0.5–35 Hz; Diagnostic: 0.05–100 Hz |
| ST Segment Range | Measure & Alarm: -2.0 to +2.0 mV |
| ARR Detection Types | Asystole, VFib/VTac, Couplet, Bigeminy, Trigeminy, R-on-T, VT>2, PVC, Tachy, Brady |
| Respiration Method | Impedance between R-F (RA-LL); differential input impedance >2.5 MΩ; measuring impedance range 0.3–5.0Ω; baseline impedance range 0–2.5 KΩ; bandwidth 0.3–2.5 Hz |
| Respiration Rate Range | Adult: 0–120 rpm; Neo/Ped: 0–150 rpm; resolution 1 rpm; accuracy ±2 rpm; apnea alarm 10–40 sec |
| SpO2 | Range 0–100%; resolution 1%; accuracy ±2% (70–100% range), unspecified below 70%; update interval ≈1 sec, alarm delay 10 sec |
| Pulse Rate (from SpO2) | Range 20–300 bpm; resolution 1 bpm; accuracy ±2 bpm |
| NIBP Method / Modes | Oscillometric; Manual, Auto, STAT (STAT period: 5 min); pulse range 40–240 bpm |
| NIBP Range – Adult / Pediatric / Neonatal | Adult SYS 40–270, DIA 10–215, MEAN 20–235 mmHg; Pediatric SYS 40–200, DIA 10–150, MEAN 20–165 mmHg; Neonatal SYS 40–135, DIA 10–100, MEAN 20–110 mmHg |
| NIBP Accuracy | Max mean error ±5mmHg; max SD ±8mmHg (test pressures: Adult 297±3, Pediatric 240±3, Neonatal 147±3 mmHg) |
| Temperature | 2 channels; range 0–50°C; resolution 0.1°C; accuracy ±0.1°C; update ≈1 sec; average time constant <10 sec |
Where This Is Used
This six-parameter patient monitor is used in ICUs, operation theatres, emergency departments and high-dependency wards where respiration rate and body temperature must be tracked alongside ECG, NIBP, SpO2 and pulse/heart rate. For simpler bedside monitoring without respiration/temperature channels, see our 5-parameter patient monitor. Browse the full Medical Diagnostic Equipment range or our complete laboratory equipment catalog.
Why Buy from Indian Lab Suppliers
Indian Lab Suppliers is an India-based laboratory and hospital equipment manufacturer and exporter supplying multi-parameter patient monitors and diagnostic instrumentation to hospitals and medical institutions. A Certificate of Origin is available on request for import documentation.
Frequently Asked Questions
How is this different from the 5-parameter patient monitor?
This model adds Respiration and Temperature monitoring on top of the ECG, NIBP, SpO2 and PR/HR parameters found in our 5-parameter patient monitor.
How is respiration measured?
By thoracic impedance measured between the R-F (RA-LL) electrodes, with a measuring range of 0.3–5.0Ω and a bandwidth of 0.3–2.5 Hz.
What arrhythmias can it detect?
Asystole, VFib/VTac, Couplet, Bigeminy, Trigeminy, R-on-T, VT>2, PVC, Tachycardia and Bradycardia.
How many temperature channels does it have?
Two channels, each measuring 0–50°C with ±0.1°C accuracy.
How is blood pressure measured?
Non-invasively, using the oscillometric method, with Manual, Auto and STAT modes and separate Adult, Pediatric and Neonatal ranges.
Related Categories
Browse the full Medical Diagnostic Equipment range, or explore our complete laboratory equipment catalog.
Request a Quote
To request pricing or a formal quotation for the Patient Monitor ECG_Sp02_BP_Remp._Respiration Monitor, please contact us or submit your requirement through our lab tender page.
